pipette
ENEnglish

A nuclear clock synchronized to 229Th

Beichen Huang, Gaowei Yan, Qi Xiao, Wenhao Bu, Chengchun Zhao, Zhen Zhang, Chao Yan, Zhi-Ang Chen, Peixiong Zhang, Gleb Penyazkov, Zhenhai Zhan, Lingfeng Yan, Yuefei Wang, Lin Li, Shanming Li, Dapeng Jiang, Xiaobo Qian, Xuegang Liu, Qiange He, Taoxiang Sun, Haochen Tian, Bing-Kun Lu, Ningyuan Ma, Juxian Li, Yanzhang Wu, Qiaorui Gong, 李玉香, Haoyu Shi, Xiangliang Li, Longsheng Ma, Shining N. Zhu, Yuxiang Mo, Jun Lin, Youyong Li, Yige Lin, Xibo Zhang, Hang Yin, Liangbi Su, Shiqian Ding

Revista con revisión por paresDice ser un gran avance

En palabras de los autores

Abstract Atomic clocks have made time and frequency the most precisely measured quantities in physics, progressing from microwave standards that realize the SI second 1 to optical clocks with unprecedented precision 2 . A nuclear clock transfers the frequency reference from an electronic to a nuclear transition and the uniquely low-lying, laser-accessible, isomeric transition in 229 Th currently offers the most practical route to compact, robust timekeeping and sensitive tests of fundamental physics 3–8 . Realizing such a clock requires turning spectroscopy of the 229 Th nuclear resonance 9–17 into a stable discriminator for steering a traceable oscillator. Here we demonstrate a 229 Th nuclear clock by stabilizing a continuous-wave, narrow-linewidth 148.4 nm vacuum-ultraviolet (VUV) laser 18 to a resolved, weakly temperature-sensitive nuclear transition 17,19 in 229 Th:CaF 2 crystals 20–22 . A 10-μW VUV source generated by four-wave mixing in cadmium vapour 18,23,24 and phototube-based frequency modulation absorption readout provide a fast, high-signal-to-noise nuclear discriminator. The clock reaches a fractional frequency instability of 5 × 1 0 − 13 / τ / s for averaging time τ . Clock-transition frequencies measured in two independently fabricated crystals agree at the 10 −13 level and are consistent with previous VUV-comb measurements on other 229 Th:CaF 2 crystals 17 . These results establish laser-addressed nuclei as operational clock references and provide a reproducible solid-state platform for compact nuclear clocks, nuclear quantum sensors and precision tests of fundamental physics.

Resultado principalEl resumen no menciona limitaciones.

En palabras simples Resumen con IA

Los investigadores construyeron un reloj nuclear usando un láser especial bloqueado a una transición nuclear en átomos de torio-229 incrustados en cristales de fluoruro de calcio. Usaron una fuente láser de vacío-ultravioleta de 10 microwatts y detección con fototubo para crear una señal rápida y de alta calidad para la estabilización del reloj. El reloj logra una inestabilidad fraccional de frecuencia de 5 × 10⁻¹³ dividida por la raíz cuadrada del tiempo de promediado en segundos. Las mediciones de dos cristales fabricados independientemente coincidieron al nivel de 10⁻¹³ y concordaron con resultados previos de otros cristales. Estos resultados muestran que los núcleos controlados por láser pueden funcionar como referencias prácticas de reloj y ofrecen una plataforma reproducible para relojes nucleares compactos y pruebas de física de precisión.

Escrito por Kimi K2.5 usando solo el abstract de arriba. Jev verificó que cada oración esté respaldada por las oraciones del abstract que cita y eliminó las que no. Pasá el cursor por una oración para ver de dónde sale.

Apareció: viernes, 9 de octubre. Nature. Revista con revisión por pares.

DOI: 10.1038/s41586-026-11122-1