A thorium-229 optical nuclear clock with feedback loop

L. Toscani De Col, T. Riebner, I. Morawetz, F. Schneider, N. Sempelmann, Juliette Schlachet-Lépinay, Fabian Schaden, Michael Bartokos, Georgy A. Kazakov, Kjeld Beeks, B. Gerstenecker, Martin Pimon, Sebastian Lahs, A. Hellerschmied, T. Lercher, Heiner Denker, J. Premper, A. Niessner, Michael Matus, M. (Martin) Čížek, O. (Ondřej) Číp, V. Lal, G. Zitzer, V. Petrov, Johannes Tiedau, Maksim V. Okhapkin, E. Peik, Thorsten Schumm

Revista con revisión por paresDice ser un gran avance

En palabras de los autores

Abstract The laser-accessible nuclear transition in the thorium-229 isotope has been identified as a candidate for realizing an optical nuclear clock 1 that might outperform current optical clocks based on electron-shell transitions in atoms or ions 2 . It is expected to be more robust against external perturbations 3,4 and to provide enhanced sensitivity in clock-based tests of the fundamental principles of physics 5,6 . Here we realize a thorium-229 nuclear clock by stabilizing a continuous-wave laser to the 148-nm nuclear transition with rapid feedback based on absorption spectroscopy 7 . The thorium-229 nuclei are embedded in a millimetre-sized, room-temperature calcium fluoride crystal. A subharmonic of the 148-nm radiation is continuously compared with a Yb + single-ion clock. The nuclear clock shows a shot-noise-limited fractional frequency instability of 3 × 1 0 − 12 / τ / s where τ is the averaging time, approaching 10 −15 instabilities over 1 day of operation. Improvements to the instability by several orders of magnitude are projected for future devices. We use the nuclear clock to constrain models of ultralight dark matter by searching for periodic fluctuations and slow drifts in the nuclear transition energy, on timescales between 20 s and 1 day. Benefitting from the enhanced sensitivity of the thorium-229 transition, these constraints compete with the best atomic clocks concerning dark matter coupling to photons and go beyond previous measurements regarding coupling to the strong force.

Resultado principalLimitación que admiten los autores

En palabras simples Resumen con IA

Los investigadores construyeron un reloj nuclear usando átomos de torio-229 dentro de un cristal a temperatura ambiente. Estabilizaron un láser a una transición nuclear de 148 nanómetros usando retroalimentación rápida de espectroscopía de absorción. El reloj alcanzó una inestabilidad de frecuencia fraccional de 3 × 10⁻¹² por raíz cuadrada del tiempo de promediado en segundos. Compararon este subarmónico continuamente con un reloj de ion único de iterbio. El equipo usó el reloj para probar modelos de materia oscura ultraligera buscando fluctuaciones de energía entre 20 segundos y 1 día.

Escrito por Kimi K2.5 usando solo el abstract de arriba. Jev verificó que cada oración esté respaldada por las oraciones del abstract que cita y eliminó las que no. Pasá el cursor por una oración para ver de dónde sale.

Apareció: viernes, 9 de octubre. Nature. Revista con revisión por pares.