Direct measurement of motor unit twitch properties using routine clinical ultrasound and optical flow
En palabras de los autores
Introduction/Aims Current motor unit assessment techniques overlook the mechanical output that underpins function and are limited: surface recordings are weighted to the superficial ~1cm and needle EMG to a ~2 mm radius. We investigated whether clinical muscle ultrasound can measure motor unit twitches directly. Methods Peripheral nerve stimulation targeted abductor digiti minimi (ADM), abductor pollicis brevis (APB) and tibialis anterior (TA). Stimulus intensity was set 10% above supramaximal and decreased in 0.01-0.05 mA steps until the Compound Muscle Action Potential (CMAP) was abolished. An 18 MHz transducer was placed transverse to the muscle, co-located with the active electrode, with video time-locked to each stimulus. Inter-frame motion was quantified using Farneback optical flow, and twitch/CMAP amplitudes compared to derive mechanical and electrical activation thresholds and a motor unit twitch index. Results We obtained 66 recordings from 22 participants (11 female, 21-63 years); 49 met prespecified quality criteria. Threshold medians (CMAP versus ultrasound) were 6.84/5.82 mA in ADM, 5.28/4.84 mA in APB and 10.34/9.83 mA in TA. The ultrasound threshold was lower than the CMAP threshold in all three muscles (ADM +0.27 mA, p = 0.009; APB +0.08 mA, p = 0.001; TA +0.21 mA, p = 0.011). A motor unit twitch index was measurable in 32/49 recordings: 14.4 in ADM, 14.9 in APB and 18.6 in TA. Median contraction/half-relaxation times for ADM, APB & TA were 80/80, 88/95 and 79/103 ms respectively; trial-to-trial variability was 5.3/8.3 ms. Discussion Clinical ultrasound can be used to directly measure clinically relevant twitch parameters such as twitch amplitude which recruits in parallel with CMAP and is not detectable with conventional clinical neurophysiology techniques. Mechanical activation is detected at slightly lower stimulus currents than the CMAP, and the twitch signal plateaus before the CMAP does; neither effect was confined to the larger muscle.
En palabras simples Resumen con IA
En los tres músculos, la ecografía detectó la activación mecánica con corrientes eléctricas ligeramente más bajas que los registros eléctricos convencionales. Midieron con éxito las propiedades de los twitches, incluyendo los tiempos de contracción y un índice de twitch de unidad motora en la mayoría de las grabaciones. Los autores concluyen que la ecografía clínica de rutina puede medir directamente parámetros de twitch que las técnicas convencionales de neurofisiología clínica no pueden detectar.
Escrito por Kimi K2.5 usando solo el abstract de arriba. Jev verificó que cada oración esté respaldada por las oraciones del abstract que cita y eliminó las que no. Pasá el cursor por una oración para ver de dónde sale. Se eliminaron 2 oraciones por no estar respaldadas por el abstract.
Apareció: jueves, 29 de octubre. medRxiv. Preprint, todavía sin revisión por pares.