Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis

R. Sriram, I. Nenadic, Z. Loring, M. Fudim, A. Mazella, A. K. Gehi, V. L. Murthy

PreprintUso en el mundo real

En palabras de los autores

Background: Rheumatic mitral stenosis (RMS) disproportionately affects low-resource settings where echocardiography is limited. We evaluated foundation model (FM) feasibility for RMS detection using limited, indirectly labeled ECGs. Methods: An ECG-FM was fine-tuned using 804 RMS-positive ECGs per fold and externally validated across clinical and wearable lead configurations. Results: Internal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively. External AUROCs were 0.82, 0.80, and 0.77. Performance remained comparable across demographic subgroups. Conclusions: FM fine-tuning enables RMS detection using limited ICD-derived labels, supporting further evaluation of reduced-lead ECG screening and echocardiography triage in resource-constrained settings.

Resultado principalLimitación que admiten los autores

Apareció: miércoles, 14 de octubre. medRxiv. Preprint, todavía sin revisión por pares.

DOI: 10.64898/2026.10.12.26365300