Lu+ optical frequency references with accuracy verified at the 19th digit
En palabras de los autores
Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.
En palabras simples Resumen con IA
Los autores construyeron dos relojes atómicos ópticos usando iones individuales de lutecio. Cada reloj tiene una incertidumbre de frecuencia fraccional cerca de 1 × 10−19. Los dos relojes concuerdan con una diferencia de frecuencia relativa medida de [−0.1 ± 5.7estad ± 1.0sist] × 10−19. Esta precisión ayudará a mejorar la cronometría internacional y permitirá pruebas de física fundamental.
Escrito por Kimi K2.5 usando solo el abstract de arriba. Jev verificó que cada oración esté respaldada por las oraciones del abstract que cita y eliminó las que no. Pasá el cursor por una oración para ver de dónde sale.
Apareció: viernes, 25 de septiembre. Nature. Revista con revisión por pares.