pipette
ENEnglish

Scalable crosslinking-regulated membranes with ultra-high Li+/Mg2+ selectivity for lithium recovery from brines

Zhen Wang, Guoshen Zeng, Yueyue Li, Changting Wang, Yang Liu, Bolun Peng, Jinhua Feng, Rongzhen Ma, Wenjie Kuang, Jianping Cao, Bei Liu, Fengliang Wang, Mariam Al Ali Al‐Maadeed, Mohammad K. Hassan, Eydhah Almatrafi, Khaled Bin Bandar, Mohammed A. Alhussaini, Saud A. Aldrees, Turki N. Baroud, Dalal Matar Al Shamsi, Ahmed Al Raeesi, Yunbo Wang, Hongjun Zhang, Kun Li, Lingyue Zhang, Wenbin Wang, Peng Wang

Revista con revisión por paresUso en el mundo real

En palabras de los autores

Abstract Membrane-based separation has emerged as a competitive technology for lithium extraction from salt-lake brines. However, its industrial implementation remains limited by the low Li + /Mg 2+ selectivity of conventional membranes. In this work, we demonstrate that regulation of the crosslinking degree during membrane formation enables subnanometer pore size control within the narrow window required for Li + /Mg 2+ separation. Under electrodialysis conditions, the membrane achieved a Li + /Mg 2+ separation factor of up to 6454 at an Mg/Li mass ratio of 140, outperforming previously reported membranes for Li + /Mg 2+ separation. Importantly, the membrane maintained a Li + /Mg 2+ separation factor above 1200 in untreated natural salt-lake brine, despite the high Mg/Li mass ratio (Mg/Li = 87) and the presence of multiple competing ions. Fabrication of a 25 cm × 35 cm membrane and stable performance over 15 days of repeated operation further supported the practical viability of this approach. The practical membrane design strategy reported in this work can inspire the development of ion-selective membranes with precisely regulated subnanometer pores for a wide range of sustainable separation processes.

Resultado principalEl resumen no menciona limitaciones.

En palabras simples Resumen con IA

Controlaron el grado de reticulación durante la formación para crear poros subnanométricos. La membrana logró un factor de separación Li+/Mg2+ de hasta 6454 en pruebas. Mantuvo un factor de separación superior a 1200 en salmuera natural sin tratar con iones competidores. Una membrana grande de 25 cm × 35 cm funcionó de manera estable durante 15 días de operación repetida.

Escrito por Kimi K2.5 usando solo el abstract de arriba. Jev verificó que cada oración esté respaldada por las oraciones del abstract que cita y eliminó las que no. Pasá el cursor por una oración para ver de dónde sale. Se eliminó 1 oración por no estar respaldada por el abstract.

Apareció: lunes, 2 de noviembre. Nature Communications. Revista con revisión por pares.

DOI: 10.1038/s41467-026-79061-z