Wavelet Transform improves time-frequency characterization of the Electroretinographic Oscillatory Potentials as compared to Short-Time Fourier Transform across experimental and clinical models

P. Reiman, S. Ghiam, A. Beryozkin, V. Stein Uman, A. Sahel, J.-F. Mouillet, L. Janeschitz-Kriegl, J. Safran, E. Shemuelian, O. Beale, S. Khateb, A. Ayalon, R. Hagan, A. Liasis, D. Stavropoulos, K.-C. Chang, T. Kuwajima, K. Mehta, I. Aldiri, A. Caspi, I. Audo, E. Banin, J.-A. Sahel, B. Rosin

PreprintUso en el mundo real

En palabras de los autores

Purpose: To compare continuous wavelet transform (CWT) and short-time Fourier transform (STFT) analyses of the oscillatory potentials (OPs) of the dark-adapted full-field electroretinogram (FFERG). Methods: FFERG recordings from Royal College of Surgeons (RCS) and healthy Brown Norway (BN) rats, wild-type and Atoh7 enhancer-knockout (KO) mice, and patients with diabetic retinopathy and healthy controls were analyzed with STFT and with CWT employing the real Morlet wavelet, after 60 Hz high-pass and sharp 60 Hz notch filtering. Time- and frequency-localized OP features were quantified and the methods compared on detection of transient OP signals. Both were additionally validated using synthetic OP-like bursts of known frequency embedded in each cohort's recorded noise. Results: CWT revealed distinct time-frequency patterns and disease-specific OP alterations across all rat, mouse, and human cohorts, with improved temporal localization and frequency resolution, whereas STFT merged transient features and was more susceptible to noise. CWT-derived dominant-frequency differences reached significance in all three models; the corresponding STFT difference reached significance only in rats (separate tests; methods not directly compared). In synthetic bursts, both methods recovered injected frequencies to within 1-2.5 Hz, but only CWT resolved two bursts separated by 15 ms. Conclusions: CWT employing the real Morlet wavelet provides a robust, physiologically relevant evaluation of OPs, with improved temporal localization and reduced spectral dispersion relative to STFT in clinical and experimental settings. Translational Relevance: CWT analysis may improve the characterization of inner retinal dysfunction by preserving transient OP time-frequency structure, as illustrated in preclinical rodent models and diabetic retinopathy patients.

Resultado principalLimitación que admiten los autores

Apareció: sábado, 3 de octubre. bioRxiv. Preprint, todavía sin revisión por pares.

DOI: 10.64898/2026.09.26.754708