Individual versus fixed parametrization of an electrocutaneous warning signal during manual work tasks

E.-M. Dölker, R. Farouk, F. Altaeh, J. Sander, J. Haueisen

PreprintUso en el mundo real

En palabras de los autores

Electrocutaneous stimulation provides a means to warn workers of potential hazards. Our previous parameter studies were conducted at rest or under controlled external influences such as vibration, temperature, and humidity, whereas actual work tasks have not yet been addressed. As a step towards greater practical applicability, we conducted two studies in which a circumferential electrocutaneous warning signal was applied to the upper right arm while participants performed a reading task, screw-driving, and polishing. In study 1 (n = 32), the pulse interval was adjusted individually to evoke a vibrating sensation, and the intolerance threshold was determined. In study 2 (n = 29), a fixed pulse interval of 36 ms was applied to all participants, the warning threshold was determined in addition to the intolerance threshold, and muscle twitches were documented both by participant report and by an independent observer. Study 1 demonstrated that electrocutaneous warning during work tasks is feasible, with a median intolerance threshold higher during polishing (16.5 mA) than during reading or screw-driving (14 mA each). In study 2, the fixed parameter setting elicited the intended pulsating or vibrating sensation at rest in 89 % of the participants in both presentations. The median warning threshold was 8 mA and did not differ between the three work tasks, whereas the intolerance threshold was lower during reading (18 mA) than during screw-driving and polishing (20 mA each). Muscle twitches were largely absent at the warning threshold and became frequent towards the intolerance threshold, with a ventral dominance of their location in both studies. An individual parametrization is therefore not required for the majority of users when a binary warning is to be conveyed, and operating the system slightly above the warning threshold provides a usable amplitude range while minimizing muscle twitches. Future work will focus on electrode optimization and on the objective measurement of motor responses.

Resultado principalLimitación que admiten los autores

Apareció: jueves, 24 de septiembre. bioRxiv. Preprint, todavía sin revisión por pares.

DOI: 10.64898/2026.09.17.749350