High-Performance Sensorless Control for High-Speed PMSM with Current Source Inverters

Nail Tosun, Devinda Molligoda, Xu Deng, Barrie Mecrow

PreprintUso en el mundo real

En palabras de los autores

Current source inverters (CSIs) are emerging as competitive alternatives to voltage source inverters (VSIs) for high-speed motor drives because they inherently suppress harmonic currents, offer output-voltage boosting, and reduce motor-side electromagnetic interference. Sensorless control of CSI-fed permanent magnet synchronous machines (PMSMs) remains less mature than VSI counterparts, primarily because conventional implementations require measurement of all circuit state variables. This paper proposes a weak-resonance-based approximation that reconstructs stator currents from inverter modulation commands and feedforward capacitor-current estimation, thereby reducing the sensing requirement to the dc-link current and two terminal voltages. The proposed observer--PLL structure is analysed for computational complexity and validated through simulations and experiments on a 100~W, 100~krpm GaN-based two-stage CSI prototype (buck + CSI). Quantitative results demonstrate accurate rotor-position tracking and high-bandwidth operation while maintaining the reduced sensor set. Proposed method performs well in simulation and experiment, achieving a position estimation error below at 100~krpm.

Resultado principalEl resumen no menciona limitaciones.

Apareció: miércoles, 23 de septiembre. arXiv. Preprint, todavía sin revisión por pares.

Comentario de los autores: Accepted, and presented at ICEM 2026