Multi-Period Repetitive Control Design in a Time Delay Framework with Application to an Active Vibration Isolation System
In the authors' words
Multi-period Repetitive Control (MPRC) can lead to amplification at non-repetitive frequencies due to the multiplication of multi-period repetitive control in their closed-loop sensitivity functions, which leads to closed-to imaginary poles. We propose a MPRC structure that eliminates such interaction. The scheme can be equivalently converted into a disturbance observer to improve robustness to frequency uncertainties. We derive an upper bound on the sensitivity function that can be optimized at either repetitive or non-repetitive frequencies. Experimental results on an active vibration isolation system show superior performance over existing robust MPRC schemes, and the capability to suppress unknown time-varying periodic disturbances.
Appeared: Tuesday, September 22. arXiv. Preprint, not yet peer-reviewed.