pipette
ESEspañol

Exhaustive white blood cell extraction and profiling across whole-slide images of blood and bone marrow smears

M. Deutges, T. Ghete, A. Namsaraeva, S. Sembill, M. Metzler, C. Marr, M. Buser

PreprintReal-world use

In the authors' words

Blood and bone marrow smears are central to diagnosing hematological disorders. While whole-slide scanning enables automated single-cell profiling at scale, the computational burden of gigapixel images has confined automated analysis to manually pre-selected regions of interest. Here, we present HemAutomaton, a framework built on neural cellular automata that extracts white blood cells across entire whole-slide images without manual region selection and with minimal annotation requirements. HemAutomaton matches the in-domain detection accuracy of Faster R-CNN while surpassing it under domain shifts, operating at a fraction of the computational cost and with over 10,000-fold fewer parameters. Across three blood cancer cohorts, we extract over 100 million single-cell images and achieve annotation-efficient differential counting via few-shot classification using a pretrained hematology foundation model. Slide-wide spatial analysis uncovers consistent blast-frequency gradients across smears and demonstrates that automated blast counts match expert evaluations within inter-expert variability. Scaling automated profiling from hundreds to tens of thousands of cells per smear overcomes conventional sampling limits and establishes the foundation for more sensitive AI supported hematological assessments.

Main resultThe abstract does not state a limitation.

In plain words AI summary

Blood and bone marrow smears are used to diagnose blood disorders. The authors created HemAutomaton, a neural network system that finds white blood cells across entire scanned slides without manual selection. HemAutomaton matches Faster R-CNN accuracy but uses far less computing power and over 10,000 times fewer parameters. The system extracted over 100 million single-cell images from three blood cancer groups and performed efficient cell counting using few-shot classification. Automated blast counts matched expert evaluations within normal expert disagreement ranges.

Written by Kimi K2.5 using only the abstract above. Jev checked that every sentence is supported by the abstract sentences it cites, and removed any that were not. Point at a sentence to highlight its source.

Appeared: Tuesday, October 27. medRxiv. Preprint, not yet peer-reviewed.

DOI: 10.64898/2026.10.23.26366335