Regenerable, closed-loop, nonenzymatic continuous glucose monitoring enabled by in situ electrochemical interfacial alkalinization
In the authors' words
Continuous glucose monitoring in interstitial fluid (ISF) is important for diabetes management, but enzyme-based sensors can lose activity, while many nonenzymatic alternatives show optimal activity in alkaline media. Here we present a regenerable wrist-worn hollow microneedle platform for closed-loop nonenzymatic ISF glucose monitoring. Negative pressure extracts ISF into a detachable sensor cartridge that separates the tissue interface from the electrochemical sensing chamber and enables rinsing and reuse. A brief cathodic step triggers the hydrogen evolution reaction (HER) at an Au–Pt/Ni foam electrode, electrochemically generating a local alkaline interface for the subsequent glucose oxidation reaction (GOR). Integrated pH feedback regulates the HER–GOR sequence. In vitro and in vivo studies demonstrate rapid ISF extraction and quasi-continuous glucose monitoring in rats, with preliminary feasibility in one human participant. This work illustrates local microenvironment regulation as a strategy for enabling alkaline-dependent glucose electrocatalysis in near-neutral ISF. Continuous glucose monitoring is central to diabetes management, yet conventional testing provides only intermittent snapshots and may miss clinically important glycaemic fluctuations. Here, the authors present a wrist-worn hollow microneedle platform that combines active interstitial fluid extraction with nonenzymatic electrochemical glucose sensing in a wearable format. Its detachable microneedle cartridge enables independent cleaning or replacement, supporting quasi-continuous monitoring while improving practicality and long-term usability for wearable glucose tracking.
In plain words AI summary
The authors developed a wrist-worn device with hollow microneedles that extracts interstitial fluid for glucose monitoring without enzymes. A detachable cartridge separates the tissue from the sensing chamber and allows rinsing and reuse. A brief electrical step generates a local alkaline environment at the electrode for glucose detection. Tests in rats showed rapid fluid extraction and quasi-continuous glucose monitoring, with early testing in one person.
Written by Kimi K2.5 using only the abstract above. Jev checked that every sentence is supported by the abstract sentences it cites, and removed any that were not. Point at a sentence to highlight its source.
Appeared: Sunday, October 18. Nature Communications. Peer-reviewed journal.