pipette
ESEspañol

Oxygen-permeable microwell plates for high-throughput spheroid culture

J. Takahashi, H. Kato, H. N. Zook, H. T. Ku, K. Iiba, S. Mizuno, K. Esashika, H. Komatsu

PreprintBold claims, read criticallyReal-world use

In the authors' words

Oxygen (O2) transport is a major limitation in high-density cell culture, particularly as three-dimensional (3D) spheroids are increasingly used to better mimic in vivo tissue environments. Here, we developed a poly(4-methyl-1-pentene) (PMP)-based microwell platform, leveraging its lower molecular absorption and greater mechanical stability than the commonly used O2-permeable polydimethylsiloxane (PDMS), while retaining high O2 permeability. We measured O2 permeability in 50-m-thick PMP membranes and found approximately 200-fold greater O2 permeability than the conventional 1-mm polystyrene culture-plate material. PMP membrane-based microwell plates with 350-m-diameter wells maintained spatial separation of pre-formed hepatocyte spheroids while supplying O2 from the plate bottom, synergistically enhancing spheroid oxygenation. Compared with non-O2-permeable plates, the platform reduced localized hypoxia and hypoxia-associated cell injury while improving spheroid viability and growth. Collectively, PMP-based O2-permeable microwell plates provide a promising, scalable, high-throughput platform for spheroid culture with multiple applications in tissue engineering, drug screening and beyond.

Main resultThe abstract does not state a limitation.

Appeared: Thursday, October 8. bioRxiv. Preprint, not yet peer-reviewed.

DOI: 10.64898/2026.10.05.756623