Pulse waveform morphology encodes haemodynamic signatures of impending stroke
In the authors' words
Stroke is a disorder of the circulation, yet the haemodynamic state that immediately precedes it has rarely been observed, because continuous physiological recordings before a stroke are seldom available. Photoplethysmography (PPG), recorded by every pulse oximeter and by hundreds of millions of wearable devices, captures the peripheral pulse beat by beat, but its morphology is largely discarded. Here we ask whether pulse waveform morphology encodes haemodynamic signatures of impending stroke. Using in-hospital stroke as a natural experiment that provides continuous PPG before physician-adjudicated stroke recognition, we studied intensive-care (MIMIC-III, ) and emergency-department (MC-MED, ) cohorts and described each beat with interpretable descriptors of pulse timing, amplitude, contour and variability. At a nominal 360-min horizon, morphology separated pre-recognition from stable windows with scores of 0.941 and 0.989 (sensitivity 0.998 and 0.980), with models transferred unchanged to the second cohort, and outperformed heart rate alone on identical windows. The signature was dominated by systolic crest time and its change from each patient's own baseline, feature attribution was concordant across cohorts (Spearman ), and morphology recorded in the first two hours of care stratified the subsequent clinical course ( 0.714 and 0.691). In high-risk patients without stroke, 29% and 14% of windows were positive, but five-window persistence rules limited alerts to 17% and 2% of patients. The results demonstrate that the routinely recorded pulse thus carries haemodynamic imprint of the period preceding stroke, positioning pulse morphology as a candidate continuous cerebrovascular biomarker.
In plain words AI summary
The researchers studied pulse waveforms from hospital patients to see if they could detect signs of stroke before doctors recognized it. The pulse morphology predicted impending stroke with F1 scores of 0.941 and 0.989, and worked better than heart rate alone. The results suggest that standard pulse recordings carry hidden information about stroke risk that could enable continuous monitoring.
Written by Kimi K2.5 using only the abstract above. Jev checked that every sentence is supported by the abstract sentences it cites, and removed any that were not. Point at a sentence to highlight its source. 2 sentences were removed for not being supported by the abstract.
Appeared: Tuesday, November 10. arXiv. Preprint, not yet peer-reviewed.
Authors' comment: 23 pages, 10 figures